Which Standard Governs Each Step of a Refrigerant Cylinder? — One-Page Map

· QUZHOU HUAFU NEW REFRIGERATION MATERIAL CO., LTD.

One page, one question: which framework fixes which part of a refrigerant cylinder.

Which standard governs each step of a refrigerant cylinder?

There is no single international standard for a refrigerant cylinder — each stage is fixed by a different instrument, and they are not interchangeable.

#StageGoverning framework / standardWhat it fixes
1Cylinder shell — constructionGB/T 5099.1-2017 (seamless) and GB/T 5100-2020 (welded), China; ISO 4706 (welded, international)Steel grade, wall thickness, design and test pressure
2Cylinder valveISO 10297Valve design and type testing
3Valve outlet — North AmericaCGA V-1Numbered outlets — CGA 320 for the R-12 / R-134a class, CGA 660 on R-22 family cylinders
4Valve outlet — EuropeDIN 477-1Threaded outlets by gas family; non-flammable refrigerant outlet = No. 6 (W 21.8 x 1/14, right-hand)
5Valve outlet — United KingdomBS 341 Part 3:2002Numbered outlets; No. 7 = flammable refrigerants (G 5/8 in, left-hand)
6Valve outlet — Australia / New ZealandAS 2473.2:2015Numbered outlets; Type 34 (G 3/4 in) = R134a
7Valve outlet — Japan and Taiwan, ChinaJIS B 8246Outlets quoted by JIS number
8Valve outlet — China domesticGB/T 15383-2011GB outlet types and dimensions
9Filling limit — United States49 CFR 173.304aFilling ratio / density per gas, referenced to 131 F (55 C)
10Filling rules — China domesticGB/T 14193.1-2025 with TSG 23-2021Filling of liquefied-gas cylinders; reference = maximum service temperature marked on the cylinder
11Filling limit — sea transportIMDG CodeLiquefied-gas filling limits per gas for the voyage
12Periodic inspection and requalificationISO 18119 / ISO 10460 (international); TSG 23-2021 (China)Inspection intervals, test methods, requalification
13Sea transportIMDG CodeClassification, packing, segregation, documentation
14Air transportIATA Dangerous Goods RegulationsPressure limits, quantities, packing
15Road and rail transportADR; 49 CFR in the United StatesFilling limits, marking, documentation — national variants apply
16Storage in the warehouseJurisdiction fire-safety regulation, with segregation principles from IMDG / ADRWhich gases may be stored together, and at what separation

What the table does, and does not, say

The specification has more than one layer: a cylinder is usable when the shell, the valve, the outlet, the fill and the transport documents all belong to the framework in force for its destination market. Satisfying one framework does not satisfy another — a CGA outlet number is not a DIN number, and the 49 CFR fill limit is not the Chinese fill rule.

How to use it on an enquiry

  1. Name the destination market.
  2. List the frameworks that apply there — shell, outlet, fill limit, transport mode.
  3. Put the outlet standard and number, and the cylinder test pressure class, into the purchase specification. “R134a cylinder” alone is incomplete.

Where our own documents sit

Quzhou Huafu stores, fills and repacks cylinders; the fill record and the marks that accompany a shipment — water capacity, tare weight, test pressure, UN number and proper shipping name, declared net weight — are issued with the shipping documents, not on the transport papers.

Related reading: how the fill limit is calculated, valve outlets by market, retest and requalification.

Sources


FAQ

Is a cylinder that is compliant in one country automatically compliant in another? No. The frameworks are separate instruments and not translations of one another — the shell, the valve outlet and the fill limit can each differ. A cylinder assembled for one market has to be checked against the framework in force for the destination.

Which framework fixes the fill limit for a gas? The transport framework in force for the route: 49 CFR for the United States, the IMDG Code for sea, ADR for road and rail, and GB/T 14193.1-2025 with TSG 23-2021 for China domestic filling. Cylinder construction standards do not set the fill limit.

Do the outlet numbers translate between frameworks? No. CGA V-1, DIN 477-1, BS 341-3, AS 2473.2, JIS B 8246 and GB/T 15383-2011 each number their own threads. A CGA number is not a DIN number.


Prepared by Quzhou Huafu New Refrigeration Material Co., Ltd — a warehousing and filling operation (storage and cylinder filling/repacking), not a manufacturer. Published 2026-10-12.